LEED v5
Commercial Interiors
Energy and Atmosphere
Minimum Energy Efficiency

CI-v5 EAp2: Minimum Energy Efficiency Required

LEEDuser overview

Explore this LEED credit

Post your questions on this credit in the forum, and click on the credit language tab to review to the LEED requirements.

Credit language

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Intent

To promote resilience and reduce the environmental and economic harms of excessive energy use and GHG emissions by achieving a minimum level of energy efficiency.

Requirements

Projects registered before January 1, 2028 may comply with either Option 1 or Option 2.

Projects registered on or after January 1, 2028 must comply with Option 2.

Option 1. ASHRAE 90.1-2019
Comply with ANSI/ASHRAE/IES Standard 90.1-2019.

For projects applying the Normative Appendix G, “Performance Rating Method,” compliance path, use the following:

  • Future source energy metric: The future source energy metric may be used in place of the “cost".
    • Replace all references to “cost” with “future source energy.” Use an electric site-to-source energy conversion factor of 2.0 based on future projections for the U.S. A lower national average value may be used as applicable for projects outside of the U.S.
    • Replace ASHRAE 90.1, Table 4.2.1.1, building performance factors (BPFs), with the BPFs derived for the future source energy metric in Table 1.
  • Alterations: For interiors project scope except initial build-out construction, apply the following ASHRAE 90.1-2022 addenda:
    • Substantial alteration: Multiply the BPF by 1.05 if the alterations are defined as a substantial alteration in ASHRAE 90.1-2022, Section G3.1.4(a).
    • Other alterations: Apply ASHRAE 90.1-2022, Section G3.3 (“Performance Calculations for Other Alterations”), replacing all references to ASHRAE 90.1-2022, Sections 5–10, prescriptive criteria with the corresponding ASHRAE 90.1-2019, Sections 5–10 criteria.

Table 1. ASHRAE 90.1-2019 — Equivalent BPFs for a Future Source Energy Metric

Building Type

Climate Zone

0A

0B

1A

1B

2A

2B

3A

3B

3C

4A

4B

4C

5A

5B

5C

6A

6B

7

8

Multifamily

0.74

0.69

0.73

0.70

0.73

0.70

0.71

0.70

0.63

0.70

0.71

0.69

0.68

0.70

0.70

0.68

0.68

0.68

0.74

Healthcare/hospital

0.72

0.72

0.73

0.73

0.74

0.71

0.72

0.74

0.71

0.72

0.73

0.71

0.74

0.73

0.80

0.73

0.77

0.78

0.79

Hotel/motel

0.72

0.71

0.72

0.71

0.71

0.70

0.71

0.73

0.72

0.71

0.73

0.73

0.71

0.73

0.74

0.70

0.72

0.70

0.70

Office

0.62

0.63

0.61

0.62

0.58

0.60

0.57

0.62

0.55

0.55

0.61

0.57

0.58

0.61

0.59

0.58

0.60

0.54

0.58

Restaurant

0.65

0.62

0.63

0.61

0.62

0.58

0.63

0.63

0.63

0.67

0.66

0.66

0.70

0.70

0.68

0.73

0.72

0.74

0.77

Retail

0.57

0.54

0.53

0.53

0.48

0.47

0.47

0.47

0.47

0.52

0.50

0.56

0.57

0.53

0.59

0.58

0.56

0.53

0.60

School

0.57

0.57

0.58

0.57

0.55

0.54

0.57

0.51

0.49

0.48

0.51

0.52

0.51

0.53

0.51

0.53

0.50

0.51

0.58

Warehouse

0.28

0.30

0.24

0.27

0.23

0.24

0.27

0.23

0.20

0.33

0.26

0.28

0.40

0.32

0.29

0.44

0.38

0.40

0.44

All others

0.65

0.62

0.64

0.62

0.57

0.54

0.57

0.56

0.58

0.59

0.57

0.60

0.60

0.59

0.65

0.62

0.62

0.61

0.64

 

OR

Option 2. ASHRAE 90.1-2022
Comply with ANSI/ASHRAE/IES Standard 90.1-2022. Use any applicable compliance path in ASHRAE 90.1, Section 4.2, or an approved equivalent standard for elements within the project scope.

For projects applying the Normative Appendix G, Performance Rating Method compliance path, one of the following metrics may be used in place of “cost”:

  • Future source energy
    • Replace all references to cost with “future source energy.” Use an electric site-to-source energy conversion factor of 2.0 based on future projections for the U.S. A lower national average value may be used as applicable for projects outside of the U.S.
    • Replace ASHRAE 90.1, Table 4.2.1.1, BPFs with the BPFs derived for the future source energy metric in Table 2.
  • Site energy or source energy documented using ASHRAE 90.1-2022, Informative Appendix I.

Table 2. ASHRAE 90.1-2022—Equivalent BPFs for a Future Source Energy Metric

Building Type

Climate Zone

0A

0B

1A

1B

2A

2B

3A

3B

3C

4A

4B

4C

5A

5B

5C

6A

6B

7

8

Multifamily

0.64

0.59

0.62

0.60

0.61

0.59

0.61

0.60

0.49

0.57

0.59

0.56

0.55

0.57

0.57

0.55

0.55

0.55

0.60

Healthcare/hospital

0.64

0.64

0.66

0.65

0.66

0.63

0.64

0.65

0.63

0.64

0.65

0.62

0.64

0.62

0.69

0.63

0.68

0.69

0.70

Hotel/motel

0.65

0.63

0.64

0.63

0.62

0.61

0.62

0.63

0.62

0.59

0.60

0.60

0.57

0.58

0.59

0.56

0.58

0.56

0.56

Office

0.54

0.54

0.53

0.54

0.49

0.52

0.49

0.52

0.45

0.46

0.52

0.47

0.48

0.51

0.48

0.48

0.50

0.45

0.49

Restaurant

0.61

0.58

0.58

0.57

0.57

0.54

0.58

0.59

0.57

0.62

0.61

0.61

0.65

0.64

0.63

0.67

0.66

0.69

0.72

Retail

0.47

0.45

0.44

0.44

0.40

0.39

0.37

0.39

0.36

0.40

0.41

0.42

0.45

0.43

0.46

0.44

0.43

0.42

0.46

School

0.52

0.53

0.53

0.53

0.51

0.51

0.53

0.48

0.46

0.43

0.48

0.47

0.45

0.49

0.46

0.46

0.44

0.44

0.48

Warehouse

0.25

0.25

0.21

0.24

0.20

0.21

0.24

0.20

0.17

0.30

0.22

0.25

0.36

0.28

0.25

0.40

0.34

0.36

0.40

All others

0.58

0.56

0.56

0.56

0.50

0.47

0.49

0.48

0.48

0.49

0.49

0.50

0.51

0.50

0.55

0.52

0.52

0.52

0.55

 

 
 
See all forum discussions about this credit »

Frequently asked questions

No results found
See all forum discussions about this credit »

What does it cost?

Cost estimates for this credit

On each BD+C v4 credit, LEEDuser offers the wisdom of a team of architects, engineers, cost estimators, and LEED experts with hundreds of LEED projects between then. They analyzed the sustainable design strategies associated with each LEED credit, but also to assign actual costs to those strategies.

Our tab contains overall cost guidance, notes on what “soft costs” to expect, and a strategy-by-strategy breakdown of what to consider and what it might cost, in percentage premiums, actual costs, or both.

This information is also available in a full PDF download in The Cost of LEED v4 report.

Learn more about The Cost of LEED v4 »

For full access, sign up now for LEEDuser Premium

Already a premium member? Log in now

Checklists

Step by step to LEED certification

LEEDuser’s checklists walk you through the key action steps you need to earn a credit, including how to avoid common pitfalls and save money.

For full access, sign up now for LEEDuser Premium

Already a premium member? Log in now

Documentation toolkit

The motherlode of cheat sheets

LEEDuser’s Documentation Toolkit is loaded with calculators to help assess credit compliance, tracking spreadsheets for materials, sample templates to help guide your narratives and LEED Online submissions, and examples of actual submissions from certified LEED projects for you to check your work against. To get your plaque, start with the right toolkit.

For full access, sign up now for LEEDuser Premium

Already a premium member? Log in now


Addenda

This credit has no LEEDuser summary

See all forum discussions about this credit »

Credit language

USGBC logo

© Copyright U.S. Green Building Council, Inc. All rights reserved.

Intent

To promote resilience and reduce the environmental and economic harms of excessive energy use and GHG emissions by achieving a minimum level of energy efficiency.

Requirements

Projects registered before January 1, 2028 may comply with either Option 1 or Option 2.

Projects registered on or after January 1, 2028 must comply with Option 2.

Option 1. ASHRAE 90.1-2019
Comply with ANSI/ASHRAE/IES Standard 90.1-2019.

For projects applying the Normative Appendix G, “Performance Rating Method,” compliance path, use the following:

  • Future source energy metric: The future source energy metric may be used in place of the “cost".
    • Replace all references to “cost” with “future source energy.” Use an electric site-to-source energy conversion factor of 2.0 based on future projections for the U.S. A lower national average value may be used as applicable for projects outside of the U.S.
    • Replace ASHRAE 90.1, Table 4.2.1.1, building performance factors (BPFs), with the BPFs derived for the future source energy metric in Table 1.
  • Alterations: For interiors project scope except initial build-out construction, apply the following ASHRAE 90.1-2022 addenda:
    • Substantial alteration: Multiply the BPF by 1.05 if the alterations are defined as a substantial alteration in ASHRAE 90.1-2022, Section G3.1.4(a).
    • Other alterations: Apply ASHRAE 90.1-2022, Section G3.3 (“Performance Calculations for Other Alterations”), replacing all references to ASHRAE 90.1-2022, Sections 5–10, prescriptive criteria with the corresponding ASHRAE 90.1-2019, Sections 5–10 criteria.

Table 1. ASHRAE 90.1-2019 — Equivalent BPFs for a Future Source Energy Metric

Building Type

Climate Zone

0A

0B

1A

1B

2A

2B

3A

3B

3C

4A

4B

4C

5A

5B

5C

6A

6B

7

8

Multifamily

0.74

0.69

0.73

0.70

0.73

0.70

0.71

0.70

0.63

0.70

0.71

0.69

0.68

0.70

0.70

0.68

0.68

0.68

0.74

Healthcare/hospital

0.72

0.72

0.73

0.73

0.74

0.71

0.72

0.74

0.71

0.72

0.73

0.71

0.74

0.73

0.80

0.73

0.77

0.78

0.79

Hotel/motel

0.72

0.71

0.72

0.71

0.71

0.70

0.71

0.73

0.72

0.71

0.73

0.73

0.71

0.73

0.74

0.70

0.72

0.70

0.70

Office

0.62

0.63

0.61

0.62

0.58

0.60

0.57

0.62

0.55

0.55

0.61

0.57

0.58

0.61

0.59

0.58

0.60

0.54

0.58

Restaurant

0.65

0.62

0.63

0.61

0.62

0.58

0.63

0.63

0.63

0.67

0.66

0.66

0.70

0.70

0.68

0.73

0.72

0.74

0.77

Retail

0.57

0.54

0.53

0.53

0.48

0.47

0.47

0.47

0.47

0.52

0.50

0.56

0.57

0.53

0.59

0.58

0.56

0.53

0.60

School

0.57

0.57

0.58

0.57

0.55

0.54

0.57

0.51

0.49

0.48

0.51

0.52

0.51

0.53

0.51

0.53

0.50

0.51

0.58

Warehouse

0.28

0.30

0.24

0.27

0.23

0.24

0.27

0.23

0.20

0.33

0.26

0.28

0.40

0.32

0.29

0.44

0.38

0.40

0.44

All others

0.65

0.62

0.64

0.62

0.57

0.54

0.57

0.56

0.58

0.59

0.57

0.60

0.60

0.59

0.65

0.62

0.62

0.61

0.64

 

OR

Option 2. ASHRAE 90.1-2022
Comply with ANSI/ASHRAE/IES Standard 90.1-2022. Use any applicable compliance path in ASHRAE 90.1, Section 4.2, or an approved equivalent standard for elements within the project scope.

For projects applying the Normative Appendix G, Performance Rating Method compliance path, one of the following metrics may be used in place of “cost”:

  • Future source energy
    • Replace all references to cost with “future source energy.” Use an electric site-to-source energy conversion factor of 2.0 based on future projections for the U.S. A lower national average value may be used as applicable for projects outside of the U.S.
    • Replace ASHRAE 90.1, Table 4.2.1.1, BPFs with the BPFs derived for the future source energy metric in Table 2.
  • Site energy or source energy documented using ASHRAE 90.1-2022, Informative Appendix I.

Table 2. ASHRAE 90.1-2022—Equivalent BPFs for a Future Source Energy Metric

Building Type

Climate Zone

0A

0B

1A

1B

2A

2B

3A

3B

3C

4A

4B

4C

5A

5B

5C

6A

6B

7

8

Multifamily

0.64

0.59

0.62

0.60

0.61

0.59

0.61

0.60

0.49

0.57

0.59

0.56

0.55

0.57

0.57

0.55

0.55

0.55

0.60

Healthcare/hospital

0.64

0.64

0.66

0.65

0.66

0.63

0.64

0.65

0.63

0.64

0.65

0.62

0.64

0.62

0.69

0.63

0.68

0.69

0.70

Hotel/motel

0.65

0.63

0.64

0.63

0.62

0.61

0.62

0.63

0.62

0.59

0.60

0.60

0.57

0.58

0.59

0.56

0.58

0.56

0.56

Office

0.54

0.54

0.53

0.54

0.49

0.52

0.49

0.52

0.45

0.46

0.52

0.47

0.48

0.51

0.48

0.48

0.50

0.45

0.49

Restaurant

0.61

0.58

0.58

0.57

0.57

0.54

0.58

0.59

0.57

0.62

0.61

0.61

0.65

0.64

0.63

0.67

0.66

0.69

0.72

Retail

0.47

0.45

0.44

0.44

0.40

0.39

0.37

0.39

0.36

0.40

0.41

0.42

0.45

0.43

0.46

0.44

0.43

0.42

0.46

School

0.52

0.53

0.53

0.53

0.51

0.51

0.53

0.48

0.46

0.43

0.48

0.47

0.45

0.49

0.46

0.46

0.44

0.44

0.48

Warehouse

0.25

0.25

0.21

0.24

0.20

0.21

0.24

0.20

0.17

0.30

0.22

0.25

0.36

0.28

0.25

0.40

0.34

0.36

0.40

All others

0.58

0.56

0.56

0.56

0.50

0.47

0.49

0.48

0.48

0.49

0.49

0.50

0.51

0.50

0.55

0.52

0.52

0.52

0.55

 

 
 
See all forum discussions about this credit »